Home Product Product Brochure Software News Contact Us

Product  

Lithium pouch cell battery analyzer for capacity, voltage and cycle

Lithium pouch cell battery analyzer for capacity, voltage and cycle
  • Lithium pouch cell battery analyzer for capacity, voltage and cycle
  • battery systems
  • battery testing machine for charging -discharging/ Voltage/internal resistance testing performance for all Ni-MH,Lithium ion cel
Model No.︰CT-4008-5V1mA
Brand Name︰NEWARE
Country of Origin︰China
Unit Price︰-
Minimum Order︰1 pc
Share on:

 Total 16 Related Items 
Prev12345Next

Product Description

NEWARE 8 channel battery analyzer CT-4008-5V1MA-164 is 8 channel battery analyzer for battery material research,each channel of the analyzer has independent constant-current and constant-voltage source, which can be programmed and controlled by computer software. NEWARE 8 channel battery analyzer CT-4008-5V1MA-164 system provides most applications in battery testing fields such as electrode materials research, battery performance test, small-scale battery formation, capability grading, battery pack testing and etc.

 

 

AC Input

AC 110V±10% 50Hz or AC 220V±10% 1

 Power

71

mW

Resolution

AD: 16bit; DA: 16bit

Input Impedance

1MΩ

Voltage

Measuring Range

Charge: 10mV~5V

Discharge: 10mV~5V

 Discharge  Min Voltage

10mV

Accuracy

± 0.1% of  FS

Stability

± 0.1% of  FS

Current

Range

Charge: 0.002mA~1mA             Discharge: 0.002mA~1mA

Accuracy

± 0.1% of  FS

Stability

± 0.1% of  FS

Power

Output Power Per Channel

5mW

Stability

± 0.2% of  FS

Time

Rise Time

 20ms (0~Full Range)

Step Time

≤ (365*24)  hour/step

Time Format 000000 (h:min:s)

Data Acquisition

Intervals

Time interval Δt:1s~60000s

Voltage interval ΔU: 10mV~5V

Current interval ΔI: 0.002mA~1mA)

Frequency

10Hz

Charge

Modeof Operation

CCC, CVC, CC & CVC,CPC,CC&CCC

End Conditions

Voltage, Current, Test Time, Capacity, -△V

Discharge

Modeof Operation

CCD, CPD,

End Conditions

Voltage, Current, Test Time, Capacity,-△V

Pulse

charge

CCC Constant power mode

 

Discharge

CCDConstant power mode

 

Min Pulse Width

500ms

Automated Switch

Automated swith from charge to discharge for each pulse

End Condition

Voltage, Test Time

DCIR testing

 

Cycle

Loop Measure Range

1~65535 times

 

Payment Terms︰TT
Product Image

Lithium pouch cell battery analyzer for capacity, voltage and cycle
Lithium pouch cell battery analyzer for capacity, voltage and cycle

battery systems
battery systems

battery testing machine for charging -discharging/ Voltage/internal resistance testing performance for all Ni-MH,Lithium ion cel
battery testing machine for charging -discharging/ Voltage/internal resistance testing performance for all Ni-MH,Lithium ion cel

Related Products
Battery and cell test equipment
Battery and cell test equipment
Battery testing system
tester system / testing machine for lithium polymer batteries
Battery testing system
lithium battery testing equipment-5V/3A,5V/5A tester,etc for all kinds battery
Battery material testing
Battery life cycles




Home  |  Product  |  Product Brochure  |  Software  |  News  |  Contact Us  |  Sitemap  |  Mobile Version
  English     简体版     繁體版

Powered by DIYTrade.com  Build your FREE website !
Find Best Price For China Products !